I.1.2 VINYL COMPOSITION TILE (VCT)

See charts in the Interior portion of Section 8 for locations and instances where VCT is an acceptable flooring material.  VCT may be used in some locations that have occasional wet areas, have very high people and equipment traffic, or require constant cleaning.  VCT installations should be designed with limited patterns and borders.  A standard 12”x12”x1/8” tile is to be used.  Provide 5% minimum overstock for future modifications.

Do not use VCT in:

Areas where multiple seams are a clean-up problem.

Clean rooms.

Laboratories.

Childcare centers.

Kitchens.

I.1.2.1 Adhesives

See the manufacturer’s recommended adhesive for the substrate the material is being installed over.  Typically, a water-resistant adhesive is used.  Adhesives that reduce or omit the use of toxic chemicals, VOCs, and pollutant emissions are preferred.  Note that LEED™ provides credits that could be relevant.

I.1.2.2 Installation

Tiles shall be quarter turned on all VCT installation applications.

Verify that concrete slabs comply with ASTM F 710 and are clean and free to curing compounds, sealers, hardeners, and other materials that would interfere with bonding adhesive. 

Apply five coats of acrylic floor polish allowing proper curing time between coats before moving furniture and equipment onto floor.          

 

 

 
 

1.1 flooring