I.8 RESTROOMS
I.8.1 TOILET PARTITIONS
Standard stalls are to be 36” wide minimum, doors are to swing out of the stall, and each stall shall have a hook on the inside of the door. Handicapped stalls are to meet all ADA requirements. Floor mounted partition systems are preferred. Toilet partitions are to be Solid plastic by Santana or approved equal.
I.8.2 URINALS
Solid plastic urinal screens shall be provided at all urinal locations. Urinals shall be wall mounted at the appropriate height. At least one urinal in each restroom shall meet ADA requirements if ADA requirements are required. Waterless urinals should be considered in all cases.
I.8.3 FLUSH VALVES
All flush valves are to be electronic, infrared or motion sensor operated. They shall not be battery powered and shall be exposed not concealed within the walls. Flush valves shall have a manual option and will have a turn off switch for cleaning.
I.8.4 FAUCETS
All faucets are to be electronic, infrared or motion sensor operated and shall incorporate a turn off switch for cleaning. Sensors shall not be battery powered. Adjustable faucets shall have instant hot water capability.
|